Refine your search:     
Report No.
 - 
Search Results: Records 1-2 displayed on this page of 2
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Heat transport analysis in a district heating and snow melting system in Sapporo and Ishikari, Hokkaido applying waste heat from GTHTR300

Kasahara, Seiji; Murata, Tetsuya*; Kamiji, Yu; Terada, Atsuhiko; Yan, X.; Inagaki, Yoshiyuki; Mori, Michitsugu*

Proceedings of 23rd International Conference on Nuclear Engineering (ICONE-23) (DVD-ROM), 11 Pages, 2015/05

A heat transport analysis of a district heating and snow melting system in Sapporo and Ishikari, Hokkaido was carried out assuming application of waste heat from GTHTR300, a design of high temperature gas-cooled reactor. The following components in the system were modeled; pipelines of the water loops between GTHTR300 and heat demand district and heat exchangers to transport the heat from the water loops to water loops in the district. Double pipes for the pipeline has disadvantage that pumping electricity consumption was 2.74 times to that of single pipes due to pressure loss in annulus channel. On the other hand, the double pipe was advantageous in less heat loss and excavation load. Heat loss was 33% smaller because heat loss from inner tube was recovered in annulus channel. Excavation area was 23% smaller because water loop was made by one double pipe. Total heat loss from the GTHTR300s to the water loop in the district was 4.2% and ratio of pump electricity to power generation from the GTHTR300s was 0.8%. In January, the maximum heat demand in a year, 97.0% of the heat demand was supplied by 2 GTHTRs. Less distance between GTHTR300 and heat demand district from 40 km to 20 km would make cost of the heat transfer system 22% smaller.

Oral presentation

Utilization of GTHTR300 waste heat for district heating and snow melting

Murata, Tetsuya*; Miwa, Shuichiro*; Sakashita, Hiroto*; Mori, Michitsugu*; Kasahara, Seiji; Yan, X.

no journal, , 

Application of a high temperature gas-cooled reactor (HTGR) for snow melting and district heating in Hokkaido was investigated. Concept design of a heat delivery system, modeling of pipes and a heat exchanger, calculation of heat supply amount from HTGR, and determination of location of the HTGRs were carried out. Sapporo and Ishikari were assumed as a heat demand district. To supply the maximum heat demand 435 MW in a year, 2 GTHTR300s, a kind of design of HTGR, were required. Though the distance from the GTHTR300 site and the heat demand district was 40 km, the temperature of the GTHTR300 waste heat was enough for the district heating. Double pipe for the heat transportation from the GTHTR300 to the district was advantageous for less heat loss and smaller excavation area. This system required 9 double pipes and more that 5000 heat exchangers.

2 (Records 1-2 displayed on this page)
  • 1